A Pipe Purchase Order Checklist: Specification, Grade and Test

Most disputes over stainless and nickel alloy pipe trace back to a place where the specification left a choice and the choice was never written down. This is the checklist that closes those gaps.

Ordering stainless steel or nickel alloy pipe is not difficult. Ordering it so that the delivered pipe matches what the design assumed is where the money goes. Almost every dispute traces back to a place where the specification leaves a choice, and the choice was never written down.

This is a checklist of those places, built from the ASME BPVC 2023 Section II material volume: SA-312, SA-789, SA-790, SA-999, SA-182 and SB-444.

1. Name the product specification, then name the grade

The most consequential line on a purchase order is the specification designation: the grade symbols are not interchangeable between specifications and, in several cases, do not exist in the specification you might expect.

SA-182 contains no F 625 and no F C-276 grade: a string search returns zero occurrences of UNS N06625 and zero of UNS N10276. Forged Alloy 625 and C-276 components are governed by SB-564, and the flanges, fittings and valves by SB-462, whose scope lists 18 UNS designations including N10276 but not N06625. A quotation written against SA-182 for a 625 forging quotes a grade that does not exist, and the mill will either decline it or offer you something else.

SA-312 is an austenitic stainless specification with no duplex rows at all: a string search returns zero for S31803, S32205 and S32750. Duplex pipe and tube run through SA-789 (tubing) and SA-790 (pipe), and duplex forgings through SA-182 under F 51, F 60, F 53 and F 55. The trade names differ too: SA-312 carries Alloy 20, Alloy 28, Alloy 29, 800, 800H, N08811, N08925 and N08926 as named rows beside the TP grades.

ComponentSpecificationGrade symbols
Austenitic stainless pipeSA-312TP304, TP304L, TP316, TP316L, TP316H, TP321, TP347, TP348, TPXM-19, TPXM-29, Alloy 20, Alloy 28, Alloy 29, 800, 800H, N08811, N08925, N08926
Stainless tubingSA-789S31803, S32205, S31500, S30400, S31600, N08925, N08926
Ferritic-austenitic pipeSA-790S31803, S32205, S31200, S32750, S32760, S82441
Stainless and alloy forgingsSA-182F 304, F 316L, F 51, F 60, F 53, F 55, F 62, F 44, F 20, F 70, F 904L — no F 625 or F C-276
Nickel alloy forgingsSB-564N06625, N10276, N06022, N04400, N08825, N08800
Nickel alloy pipe and tubeSB-444N06625, N06852, N06219

2. Specify the condition, not just the alloy

An alloy name does not identify a material. SB-444 is the clearest example: UNS N06625 comes in two grades of different heat-treated condition, and the grade decides the service envelope.

SB-444 §1.1.1.1 states that Grade 1 (annealed) material is normally employed in service temperatures up to 1100 °F (593 °C). §1.1.1.2 states that Grade 2 (solution annealed) material is normally employed above 1100 °F (593 °C) when resistance to creep and rupture is required. Grade 1 is the stronger grade, so it looks like an upgrade, and it is the wrong choice above 1100 °F precisely because it is not the solution-annealed condition. The specification removes the ambiguity if you let it: §4.1.3.1 states that if neither grade of N06625 is specified, Grade 1 will be supplied, so a buyer who needs Grade 2 has to write it down. NOTE 1 to §1.1.1 adds a warning worth reading every time: hot-working or reannealing may change properties significantly, depending on working history.

3. Specify the test, because the default is the mill’s choice

Several specifications leave the type of test to the manufacturer unless the purchase order says otherwise. SA-789 §10.1 states that each tube shall be subjected to the nondestructive electric test or the hydrostatic test, and that the type of test shall be at the option of the manufacturer unless otherwise specified in the purchase order. SB-444 §4.1.7 asks the purchaser to specify the type of test, and §4.1.8 the hydrostatic pressure where it differs from the §9.1.1 default.

SA-999 §22.2.1 sets the standard basis. Each length of pipe shall be tested by the manufacturer to a hydrostatic pressure producing in the pipe wall a stress not less than 60 % of the specified minimum yield strength for ferritic alloy steel and stainless steel pipe, or 50 % for austenitic alloy and stainless steel pipe and for ferritic/austenitic stainless steel pipe, with the pressure following P = 2St/D or S = PD/2t. §22.2.1.1 rounds the test pressure to the nearest 50 psi below 1000 psi and 100 psi above it, and §22.2.4 requires a 5 s minimum hold, longer for welded pipe so the whole seam can be inspected.

At NPS 10 and above, SA-312 §12.3 allows the purchaser, with the manufacturer’s agreement, to waive the hydrostatic test in favour of a purchaser system test. Every length furnished without the completed manufacturer’s hydrostatic test must then carry the letters “NH” with its mandatory marking, and §17.1 requires that marking to include the NPS or OD and schedule number or average wall thickness, the heat number, and NH. That waiver leaves a permanent trace on the pipe.

One more clause catches people out: SA-999 §22.2.5 states the hydrostatic test may not be capable of testing the end portion of the pipe, and that length shall be determined by the manufacturer and, if the purchase order so specifies, reported to the purchaser.

4. Invoke the supplementary requirements you want

Almost every supplementary requirement applies only when the purchaser specifies it in the order. SA-312 says so in terms: one or more of the following supplementary requirements shall apply only when specified in the purchase order. SA-961 adds that they shall be made at the place of manufacture unless otherwise agreed, at the purchaser’s expense, and witnessed by the purchaser’s inspector if so specified.

RequirementSpecWhat it does
S1 Product analysisSA-312One product analysis per ten lengths per heat for pipe NPS 5 and larger
S2 Transverse tensionSA-312One test from one end of 10 % of lengths per heat, pipe NPS 8 and larger only
S5 Radiographic examSA-312Weld in each double welded pipe radiographed per UW-51; pipe marked “RT”
S8 Minimum wallSA-312Pipe furnished on a minimum wall basis; pipe marked “S8”
S9 Weld decay testSA-312One sample per lot in boiling 50 % hydrochloric acid, including the entire weld
S58 Weld repair approvalSA-961No repair welding without prior purchaser approval
S60 PMISA-961Forgings examined per Guide E1916, 100 % of them; wrong-grade forgings rejected
S4 Corrosion testsSA-182All austenitic stainless steels pass intergranular corrosion tests per A262 Practice E

5. Specify the certification, then read what you receive

SA-999 §25.1 requires that the manufacturer or supplier furnish a certificate of compliance stating that the product was manufactured, sampled, tested and inspected in accordance with the specification, including the year-date, the supplementary requirements, and any other requirements designated in the purchase order or contract. A signature is not required, but the document shall be dated and shall clearly identify the submitting organization. §25.1.1 makes the point that matters: notwithstanding the absence of a signature, the certifying organization is responsible for the contents.

§25.2 lists what the test report must include: heat number, heat analysis, product analysis if specified, tensile properties, bend and flattening test results, hydrostatic test pressure, nondestructive electric test method, impact test results, and any other results the product specification requires.

Two clauses govern what the certificate says about the things that are easy to miss. SA-312 §16.1 requires that the certification state whether or not the material was hydrostatically tested, and that if it was nondestructively tested, which standard practice was followed and what reference discontinuities were used. And SA-312 §15.4 requires that pipes with weld seam repairs be uniquely identified on the certificate of tests, with the filler metal identified when it is not the Table 6 filler. A certificate silent on all three has not told you what was done to the pipe.

A short pre-order checklist

  • Specification and grade. The product specification plus the exact grade symbol, verified against that specification. Do not assume SA-182 covers 625 or C-276.
  • Condition. For N06625, the grade; for anything with a condition option, the condition.
  • Dimensions. OD, wall, length, quantity. If minimum wall matters, invoke S8.
  • Test. Hydrostatic or NDE, stated explicitly, with the pressure if it differs from the default.
  • Supplementary requirements. Named by number, not described. SA-312: S1, S2, S3, S5, S8, S9. SA-961: S58, S59, S60. SA-182: S3, S4, S5, S6, S8.
  • Certification and marking. Whether the certificate must state the test performed and the reference discontinuities, whether the purchaser inspector is to witness, and any extra marking required, including weight above NPS 4.

Send us the grade, the dimensions, the quantity and the service conditions, and we will confirm what the specifications allow, which supplementary requirements apply and where the mill has a choice you might want to close. Reach us on WhatsApp at +86 186 2137 7760 or through our contact page, and ask about our super duplex 2507 seamless pipe or our 904L and 6Mo seamless pipe range when the grade is what you need to settle before the enquiry goes out.

Related products: nickel alloy seamless pipe and tube · Inconel 625 seamless pipe · Hastelloy C-276 seamless pipe · pipe and tube. Supplied to the applicable ASTM / ASME specifications with EN 10204 3.1 mill test certificates; confirm grade, size and quantity with our engineers.

Editorial note (November 2026): This checklist has been reviewed against the current material-family structure. For grade and standard cross-references see our nickel alloys and duplex stainless steels ranges. The applicable ASTM / ASME edition and all inspection requirements remain subject to the project specification.