The problem with a grade number
A grade number on an enquiry does not tell a mill what to make. It tells you the alloy, and leaves the manufacturing route, the delivery condition, the dimensional basis and the general requirements volume entirely open. This is a cross-reference of the pipe and tube specifications by product form. It answers a different question: if I order this alloy in this form, which document governs it, and what else does that document decide?
| Specification | Alloy / UNS | Product form | Delivery condition | General requirements |
|---|---|---|---|---|
| SB-444 | N06625, N06852, N06219 | Cold-worked seamless pipe and tube | Grade 1 annealed / Grade 2 solution annealed | SB-829 |
| SB-705 | N06625, N06219, N08825 | Welded pipe, annealed | Cold-worked in the weld metal or in weld and base metal | SB-775 |
| SB-423 | N08825, N08221 | Seamless pipe and tube | Cold-worked or hot-finished annealed | SB-829 |
| SB-407 | N08120, N08800, N08810, N08811, N08801, N08890, N06811 | Seamless pipe and tube | Cold-worked or hot-finished annealed | SB-829 |
| SB-514 | N08120, N08800, N08810 | Welded pipe | Cold-worked and annealed | SB-775 |
| SB-622 | 34 alloys incl. N10276, N06022 | Seamless pipe and tube | Solution annealed and descaled | SB-829 |
| SB-729 | N08020, N08026, N08024 | Seamless pipe and tube | Three conditions, one per UNS | SB-829 |
| SB-165 | N04400 | Cold-worked seamless pipe and tube | Annealed / stress relieved | SB-829 |
| SB-161 | N02200, N02201 | Cold-worked seamless pipe and tube | Conditions per Table 1 | SB-829 |
| SB-167 | Nickel-chromium-aluminum, nickel-chromium-iron, nickel-chromium-cobalt-molybdenum, nickel-iron-chromium-tungsten and nickel-chromium-molybdenum-copper alloys incl. N06600, N06617, N06674, N06235 | Seamless pipe and tube | Cold-worked, hot-worked or hot-finished annealed | SB-829 |
| SB-163 | Nickel and nickel alloys | Seamless tube, condenser and heat-exchanger service | Average wall or minimum wall if specified | SB-829 |
Two structural facts fall out of the table, and both trip up buyers.
First, SB-444 covers three alloys, not one. The scope reads nickel-chromium-molybdenum-columbium alloys UNS N06625 and N06852, and nickel-chromium-molybdenum-silicon alloy UNS N06219, in the form of cold-worked seamless pipe and tube. If a project wants 625 in welded pipe, SB-444 is the wrong document — SB-705 covers welded N06625, N06219 and N08825, and adds N08825 which SB-444 does not.
Second, the same UNS number appears under more than one specification with different strengths. UNS N08825 is the clearest case, because it sits in both a seamless and a welded specification. SB-423 Table 2 gives cold-worked annealed N08825 a minimum tensile strength of 85 ksi (586 MPa) and yield of 35 ksi (241 MPa), while hot-finished annealed N08825 in the same table carries 75 ksi (517 MPa) and 25 ksi (172 MPa) yield. SB-705 Table 2 gives welded N08825 the same 85 ksi (586 MPa) and 35 ksi (240 MPa) values. UNS N08800 shows the same split the other way: SB-407 Table 2 gives cold-worked annealed N08800 75 ksi (520 MPa) with 30 ksi (205 MPa) yield, and hot-finished annealed N08800 only 65 ksi (450 MPa) with 25 ksi (170 MPa) yield.
The delivery condition is not a detail
SB-729 is the clearest case, because it carries three UNS numbers in one specification and gives each a different delivery condition. Section 5.1 states that the product of UNS N08020 shall be furnished in the stabilized-annealed condition, UNS N08026 in the solution-annealed condition, and UNS N08024 in the annealed condition. Note 1 adds the recommended annealing temperatures, all followed by quenching in water or rapid cooling: 1800 to 1850 °F (982 to 1010 °C) for N08020, 2050 to 2200 °F (1121 to 1204 °C) for N08026, and 1925 to 1975 °F (1052 to 1079 °C) for N08024. The mechanical properties are identical across all three at 80 ksi (550 MPa) tensile and 35 ksi (240 MPa) yield — so the chemistry and the delivery condition do the differentiating, not the strength.
SB-165 takes the opposite approach and makes the condition depend on size. Table 1 sets annealed material at 70 000 psi (480 MPa) tensile and 28 000 psi (195 MPa) yield for 5 in. (127 mm) outside diameter and under, dropping to 25 000 psi (170 MPa) yield above that size, while the stress-relieved condition across all sizes goes the other way, to 85 000 psi (585 MPa) tensile and 55 000 psi (380 MPa) yield with elongation down to 15 %. SB-622 behaves differently again: Section 1.2 requires that pipe and tube shall be supplied in the solution annealed and descaled condition, because the condition is a requirement rather than an option.
Which general requirements volume sits behind the product
SB-829 is the general requirements volume for seamless nickel alloy pipe and tube, and its Section 1.1 lists the seamless product specifications it governs: B161, B163, B165, B167, B407, B423, B444, B535, B570, B622, B668, B677, B690, B722 and B729. SB-775 is the equivalent for longitudinally welded nickel and nickel alloy pipe, listing B464, B514, B517, B619, B673, B675, B705, B723 and B725 — a different list, because the products are different. Both volumes except Sections 5 and 10 from the mandatory requirements, and both make the same point in Section 1.2: one or more of the Section 5 test requirements apply only if specifically stated in the product specification or in the purchase order.
The practical consequence shows up in three places:
- Marking. SB-829 Section 14.1.1 requires the manufacturer name or brand, the material name or UNS number, the letters ASTM, the product specification number, heat number, class if applicable and nominal size to be legibly marked on each piece 3/4 in. (19.0 mm) outside diameter and larger and lengths greater than 3 ft (914 mm), with smaller material allowed to carry the information on a bundle or box tag. SB-775 Section 14.1.1 sets the same threshold at 1/2 NPS and larger — different products, different marking trigger points, which is what a receiving inspector notices.
- Certification and retests. SB-775 Section 13 requires a manufacturer’s certification stating that the material has been manufactured, tested and inspected in accordance with the specification, and Section 9.1 allows retests on additional pipes of double the original number from the same group or lot. SB-829 places its certification in Section 16.
- Which rule wins. SB-829 Section 1.3 resolves conflicts explicitly: where a requirement of the product specification conflicts with one of this general specification, only the product specification needs to be satisfied.
The dimension and tolerance layer sits under all of it
Dimensional acceptance for nickel alloy pipe is not set by the material specification. SB-829 Table 1 and SB-775 Table 1 are both reprints of Table 1 of ANSI B36.19, and the permissible variations sit in Table 2 of each general requirements volume — so the general requirements volume you have already identified also decides your tolerances. And those tolerances are asymmetric, not a single ± figure.
Over 8⅝ in. (219 mm) to 14 in. (356 mm), SB-829 Table 2 permits +0.062 in. (1.57 mm) / −0.031 in. (0.79 mm) on outside diameter and +15.0 % / −12.5 % on specified minimum wall; over 14 in. (356 mm) to 24 in. (610 mm) the outside diameter band widens to +0.125 in. (3.18 mm) / −0.031 in. (0.79 mm). For welded pipe, SB-775 Table 2 Note C caps the wall thickness variation at ±12.5 % of nominal wall, and Note B carries the ovality rule.
Compressing an asymmetric tolerance into a single ± column doubles the negative tolerance and turns conforming pipe into a rejection on arrival. The full schedule tables and both tolerance tables are set out in our ANSI B36.19 nickel alloy pipe dimensions reference.
A short checklist for the enquiry
- Name the product specification, not just the alloy. SB-444, SB-705, SB-423, SB-407, SB-514, SB-622, SB-729 and SB-165 do not cover the same thing.
- Name the delivery condition. Hot-finished or cold-worked annealed for N08825 and N08800; for SB-729, name the UNS number, because the condition follows it; and for SB-165, name both the condition and the size band, because the yield requirement changes with it.
- Say which general requirements volume you are ordering against. Seamless product specifications route to SB-829, welded ones to SB-775.
- State the dimensional standard and the tolerance basis. Nominal pipe size and schedule, or outside diameter with nominal or minimum wall, and confirm you want the asymmetric figures reproduced as published rather than as a single ±.
- Put the supplementary requirements in writing. Section 5 test requirements apply only if specifically stated in the product specification or the purchase order, and the marking threshold differs: 3/4 in. outside diameter for seamless, 1/2 NPS for welded.
Our nickel alloy seamless pipe and tube page covers the seamless cold-worked and solution-annealed routes, and the pipe and tube product category lists the welded and seamless ranges side by side. If you have an order in hand and want the specification list checked against the ASME material volume before it goes to the mill, send us the grade, the product form, the size and the service conditions. For lead times and current stock, contact our export desk through the enquiry form or message us on WhatsApp.
Related products: nickel alloy seamless pipe and tube · Inconel 625 seamless pipe · Hastelloy C-276 seamless pipe · pipe and tube. Supplied to the applicable ASTM / ASME specifications with EN 10204 3.1 mill test certificates; confirm grade, size and quantity with our engineers.