Hastelloy C-276 Seamless Pipe is supplied by Hefei Tailan Metal to ASME SB-622, ASME SB-829, with an EN 10204 3.1 mill test certificate on every lot. Our seamless and welded nickel alloy pipe range covers OD 6-610 mm and wall 0.5-40 mm. Send us your grade, size and quantity and our engineers will reply within 8 working hours.
Hastelloy C-276 seamless pipe (UNS N10276) is a nickel-chromium-molybdenum-tungsten alloy produced to ASME SB-622. It is the general purpose corrosion workhorse of the nickel alloy family, with roughly 16% chromium, 16% molybdenum and 4% tungsten. Very low carbon and silicon levels give it outstanding resistance to intergranular corrosion in the weld heat-affected zone, which is what allows it to be used in as-welded fabrication.
C-276 handles both reducing acids such as hydrochloric and sulphuric acid, and oxidising media such as wet chlorine, hypochlorite and nitric acid, which is unusual for a single alloy and is why it appears in almost every chemical process plant.
Specification and Designation
| Designation | Value |
|---|---|
| UNS number | N10276 |
| ASME specification | SB-622 |
| ASTM equivalent | B622 (seamless pipe and tube) |
| Material class | Low-carbon Ni-Cr-Mo-W alloy |
Chemical Composition (ASME SB-622, Table 1)
| Element | Composition, % | Element | Composition, % |
|---|---|---|---|
| Nickel | Remainder | Carbon | 0.010 max |
| Chromium | 14.5 – 16.5 | Silicon | 0.08 max |
| Molybdenum | 15.0 – 17.0 | Cobalt | 2.5 max |
| Tungsten | 3.0 – 4.5 | Manganese | 1.0 max |
| Iron | 4.0 – 7.0 | Vanadium | 0.35 max |
| Phosphorus | 0.04 max | Sulfur | 0.03 max |
Limits quoted directly from ASME BPVC Section II Part B, SB-622 Table 1. The tight carbon (0.010 max) and silicon (0.08 max) maxima are the signature of this alloy.
C-276 versus C-22 and B-2
| Alloy | UNS | Cr, % | Mo, % | W, % | Character |
|---|---|---|---|---|---|
| C-276 | N10276 | 14.5–16.5 | 15.0–17.0 | 3.0–4.5 | Broadest, best all-round corrosion resistance, best weldability |
| C-22 | N06022 | 20.0–22.5 | 12.5–14.5 | 2.5–3.5 | Better in strongly oxidising acid such as nitric |
| B-2 | N10665 | 26.0–30.0 | 4.0–6.0 | — | Best in strong reducing acid, but prone to HAZ attack |
All three are supplied by us. The practical rule: choose C-276 as the default, C-22 for nitric-dominant oxidising service, B-2 only where reducing acid dominates and the fabrication can be solution annealed after welding.
Supply Range
| Parameter | Range |
|---|---|
| Outer diameter | 6 mm – 610 mm (1/4″ – 24″) |
| Wall thickness | 0.5 mm – 40 mm |
| Length | Random length, or cut to customer requirement |
| Condition | Solution annealed |
For the full size range of pipe and tube we supply in this and the other nickel alloys, see nickel alloy seamless pipe and tube dimensions. The dimensional and tolerance reference this page draws on is published as ANSI B36.19 dimensional and tolerance tables.
Standard Dimensions and Wall Thickness (ANSI B36.19 Schedule Table)
Every size below is the nominal dimension published in ANSI B36.19, reproduced from ASME SB-829 Table 1 — the general-requirements specification for nickel and nickel-alloy seamless pipe and tube through which SB-622 (Hastelloy C-276), SB-444 (Inconel 625), SB-167 (Inconel 600) and SB-423 (Incoloy 825) route their dimensional requirements. ASME SB-622 Table X2.1 reproduces the same schedule for this alloy. The decimal thicknesses are nominal or average wall dimensions, which is how ASME defines them.
| NPS | OD (in) | OD (mm) | Sch 5S (in / mm) | Sch 10S (in / mm) | Sch 40S (in / mm) | Sch 80S (in / mm) |
|---|---|---|---|---|---|---|
| 1⁄8 | 0.405 | 10.29 | — | 0.049 / 1.24 | 0.068 / 1.73 | 0.095 / 2.41 |
| 1⁄4 | 0.54 | 13.72 | — | 0.065 / 1.65 | 0.088 / 2.24 | 0.119 / 3.02 |
| 3–8 | 0.675 | 17.15 | — | 0.065 / 1.65 | 0.091 / 2.31 | 0.126 / 3.2 |
| 1⁄2 | 0.84 | 21.34 | 0.065 / 1.65 | 0.083 / 2.11 | 0.109 / 2.77 | 0.147 / 3.73 |
| 3–4 | 1.05 | 26.67 | 0.065 / 1.65 | 0.083 / 2.11 | 0.113 / 2.87 | 0.154 / 3.91 |
| 1 | 1.315 | 33.4 | 0.065 / 1.65 | 0.109 / 2.77 | 0.133 / 3.38 | 0.179 / 4.55 |
| 11–4 | 1.66 | 42.16 | 0.065 / 1.65 | 0.109 / 2.77 | 0.14 / 3.56 | 0.191 / 4.85 |
| 11–2 | 1.9 | 48.26 | 0.065 / 1.65 | 0.109 / 2.77 | 0.145 / 3.68 | 0.2 / 5.08 |
| 2 | 2.375 | 60.33 | 0.065 / 1.65 | 0.109 / 2.77 | 0.154 / 3.91 | 0.218 / 5.54 |
| 21–2 | 2.875 | 73.03 | 0.083 / 2.11 | 0.12 / 3.05 | 0.203 / 5.16 | 0.276 / 7.01 |
| 3 | 3.5 | 88.9 | 0.083 / 2.11 | 0.12 / 3.05 | 0.216 / 5.49 | 0.3 / 7.62 |
| 31–2 | 4 | 101.6 | 0.083 / 2.11 | 0.12 / 3.05 | 0.226 / 5.74 | 0.318 / 8.08 |
| 4 | 4.5 | 114.3 | 0.083 / 2.11 | 0.12 / 3.05 | 0.237 / 6.02 | 0.337 / 8.56 |
| 5 | 5.563 | 141.3 | 0.109 / 2.77 | 0.134 / 3.4 | 0.258 / 6.55 | 0.375 / 9.52 |
| 6 | 6.625 | 168.28 | 0.109 / 2.77 | 0.134 / 3.4 | 0.28 / 7.11 | 0.432 / 10.97 |
| 8 | 8.625 | 219.08 | 0.109 / 2.77 | 0.148 / 3.76 | 0.322 / 8.18 | 0.5 / 12.7 |
| 10 | 10.75 | 273.05 | 0.134 / 3.4 | 0.165 / 4.19 | 0.365 / 9.27 | 0.5 / 12.7 |
| 12 | 12.75 | 323.85 | 0.156 / 3.96 | 0.18 / 4.57 | 0.375 / 9.52 | 0.5 / 12.7 |
| 14 | 14 | 355.6 | 0.156 / 3.96 | 0.188 / 4.78 | — | — |
| 16 | 16 | 406.4 | 0.165 / 4.19 | 0.188 / 4.78 | — | — |
| 18 | 18 | 457.2 | 0.165 / 4.19 | 0.188 / 4.78 | — | — |
| 20 | 20 | 508 | 0.188 / 4.78 | 0.218 / 5.54 | — | — |
| 22 | 22 | 558.8 | 0.188 / 4.78 | 0.218 / 5.54 | — | — |
| 24 | 24 | 609.6 | 0.218 / 5.54 | 0.25 / 6.35 | — | — |
| 30 | 30 | 762 | 0.25 / 6.35 | 0.312 / 7.92 | — | — |
Note A — Schedules 5S and 10S wall thicknesses do not permit threading in accordance with ANSI B1.20.1. Note B — These do not conform to ANSI B36.10.
Permissible Variations and Tolerances
Nominal size is not delivered size. The permissible variations for outside diameter and wall thickness of seamless cold-worked pipe and tube are set out in ASME SB-829 Table 2. They are the tolerances a mill is permitted to work to, and they are what you should hold the supplier to when the pipe arrives. State them on the purchase order so acceptance is objective rather than a conversation. ASME prints the plus and minus limits separately, and the two largest diameter bands are asymmetric: on pipe over 8⁄5⁄8 in. the outside diameter may run over by more than it may run under, and the minimum wall is allowed 15.0 % over but only 12.5 % under. A supplier quoting a single tolerance figure for these sizes is quoting something other than the standard.
| Nominal outside diameter (in / mm) | Outside diameter variation, plus (in / mm) | Outside diameter variation, minus (in / mm) | Specified minimum wall, plus (%) | Specified minimum wall, minus (%) | Specified nominal wall, plus (%) | Specified nominal wall, minus (%) |
|---|---|---|---|---|---|---|
| Over 0.400 (10) to 5⁄8 (16), excl | 0.005 (0.13) | 0.005 (0.13) | 15 | 15 | 30 | 0 |
| 5⁄8 (16) to 11⁄2 (38), incl | 0.0075 (0.19) | 0.0075 (0.19) | 10 | 10 | 22 | 0 |
| Over 11⁄2 (38) to 3 (76), incl | 0.01 (0.25) | 0.01 (0.25) | 10 | 10 | 22 | 0 |
| Over 3 (76) to 41⁄2 (114), incl | 0.015 (0.38) | 0.015 (0.38) | 10 | 10 | 22 | 0 |
| Over 41⁄2 (114) to 6 (152), incl | 0.02 (0.51) | 0.02 (0.51) | 12.5 | 12.5 | 28 | 0 |
| Over 6 (152) to 65⁄8 (168), incl | 0.025 (0.64) | 0.025 (0.64) | 12.5 | 12.5 | 28 | 0 |
| Over 65⁄8 (168) to 85⁄8 (219), incl | 0.031 (0.79) | 0.031 (0.79) | 12.5 | 12.5 | 28 | 0 |
| Over 8.625 (219) to 14 (356), incl | 0.062 (1.57) | 0.031 (0.79) | 15 | 12.5 | 30 | 0 |
| Over 14 (356) to 24 (610), incl | 0.125 (3.18) | 0.031 (0.79) | 15 | 12.5 | 30 | 0 |
Design Density and Theoretical Weight
Every mass certificate for C-276 pipe is calculated from a density, and the specification does not leave that to the mill judgement. ASME SB-622 9.1 states: “For calculation of mass or weight, the following densities shall be used.” For UNS N10276 that is 0.321 lb/in³ (8.87 g/cm³).
| Alloy | UNS | Density, lb/in³ | Density, g/cm³ |
|---|---|---|---|
| C-276 | N10276 | 0.321 | 8.87 |
| C-22 | N06022 | 0.314 | 8.69 |
| B-2 | N10665 | 0.333 | 9.22 |
| Alloy B | N10001 | 0.334 | 9.24 |
These are the densities ASME requires for mass and weight calculation on C-276, C-22, B-2 and Alloy B pipe. They are not estimates. Where a supplier quotes a weight from a different figure — a generic “8.9” for a nickel alloy, or a carbon-steel 7.85 — the weight on the quotation and the weight on the mill certificate will not agree, and the freight invoice is settled on the certificate.
The theoretical weight below is computed from the ASME B36.19 nominal outside diameter and wall thickness for each schedule, at the SB-622 density of 8.87 g/cm³:
kg / m = density (g/cm³) × π × wall (mm) × (OD (mm) − wall (mm)) ÷ 1000
| NPS | OD (mm) | Sch 10S (kg / m) | Sch 40S (kg / m) | Sch 80S (kg / m) |
|---|---|---|---|---|
| 1⁄8 | 10.29 | 0.31 | 0.41 | 0.53 |
| 1⁄4 | 13.72 | 0.55 | 0.72 | 0.90 |
| 3–8 | 17.15 | 0.71 | 0.96 | 1.24 |
| 1⁄2 | 21.34 | 1.13 | 1.43 | 1.83 |
| 3–4 | 26.67 | 1.44 | 1.90 | 2.48 |
| 1 | 33.4 | 2.36 | 2.83 | 3.66 |
| 11–4 | 42.16 | 3.04 | 3.83 | 5.04 |
| 11–2 | 48.26 | 3.51 | 4.57 | 6.11 |
| 2 | 60.33 | 4.44 | 6.15 | 8.46 |
| 21–2 | 73.03 | 5.95 | 9.76 | 12.90 |
| 3 | 88.9 | 7.30 | 12.76 | 17.26 |
| 31–2 | 101.6 | 8.38 | 15.33 | 21.06 |
| 4 | 114.3 | 9.46 | 18.16 | 25.22 |
| 5 | 141.3 | 13.07 | 24.59 | 34.96 |
| 6 | 168.28 | 15.62 | 31.93 | 48.09 |
| 8 | 219.08 | 22.56 | 48.07 | 73.04 |
| 10 | 273.05 | 31.39 | 68.14 | 92.14 |
| 12 | 323.85 | 40.66 | 83.39 | 110.12 |
| 14 | 355.6 | 46.73 | — | — |
| 16 | 406.4 | 53.50 | — | — |
| 18 | 457.2 | 60.26 | — | — |
| 20 | 508 | 77.57 | — | — |
| 22 | 558.8 | 85.41 | — | — |
| 24 | 609.6 | 106.74 | — | — |
| 30 | 762 | 166.42 | — | — |
The same table in pounds per foot:
| NPS | OD (mm) | Sch 10S (lb / ft) | Sch 40S (lb / ft) | Sch 80S (lb / ft) |
|---|---|---|---|---|
| 1⁄8 | 10.29 | 0.69 | 0.91 | 1.17 |
| 1⁄4 | 13.72 | 1.22 | 1.58 | 1.99 |
| 3–8 | 17.15 | 1.57 | 2.11 | 2.74 |
| 1⁄2 | 21.34 | 2.49 | 3.16 | 4.04 |
| 3–4 | 26.67 | 3.18 | 4.20 | 5.47 |
| 1 | 33.4 | 5.21 | 6.23 | 8.06 |
| 11–4 | 42.16 | 6.70 | 8.44 | 11.12 |
| 11–2 | 48.26 | 7.74 | 10.08 | 13.48 |
| 2 | 60.33 | 9.80 | 13.55 | 18.65 |
| 21–2 | 73.03 | 13.11 | 21.51 | 28.43 |
| 3 | 88.9 | 16.09 | 28.13 | 38.05 |
| 31–2 | 101.6 | 18.47 | 33.80 | 46.42 |
| 4 | 114.3 | 20.85 | 40.05 | 55.61 |
| 5 | 141.3 | 28.80 | 54.22 | 77.07 |
| 6 | 168.28 | 34.44 | 70.40 | 106.02 |
| 8 | 219.08 | 49.74 | 105.98 | 161.02 |
| 10 | 273.05 | 69.21 | 150.22 | 203.13 |
| 12 | 323.85 | 89.64 | 183.84 | 242.76 |
| 14 | 355.6 | 103.02 | — | — |
| 16 | 406.4 | 117.94 | — | — |
| 18 | 457.2 | 132.85 | — | — |
| 20 | 508 | 171.01 | — | — |
| 22 | 558.8 | 188.30 | — | — |
| 24 | 609.6 | 235.33 | — | — |
| 30 | 762 | 366.90 | — | — |
These are theoretical weights from nominal dimensions. Delivered weight will differ, because the wall thickness you receive is subject to the permissible variations published in ASME SB-829 Table 2 above. For the size and tolerance cross-reference across the nickel alloy pipe and tube products we supply, see our ASME B36.19 permissible variations and schedule tables.
Testing and Inspection
- EN 10204 3.1 mill test certificate, third-party inspection available on request
- Hydrostatic or nondestructive electric test on every tube
- Full chemical analysis; actual heat values shown on the certificate
- Intergranular corrosion test to ASTM G28 (typically practice A or C depending on service) available on request
- Ferrite content check on weld consumables where required by the applicable code
- Dye penetrant inspection on all pipe; ultrasonic testing on heavy wall and forgings
Surface, Marking and Packing
Solution annealed with a pickled or bright annealed surface, capped both ends and individually sleeved. Marked with heat number, grade, standard, size and works mark. Export packing in wooden cases or steel pallets with plastic end caps.
Hydrostatic Test Pressure and Allowable Fibre Stress (ASME SB-622 / SB-829)
Hastelloy C-276 seamless pipe is hydrostatically tested or examined by an electric method to ASME SB-829, and the allowable fibre stress that governs the test is the one computed from the mechanical properties in SB-622 Table 2. SB-829 5.2 sets the rule: each length is tested to an internal pressure of 1000 psi (6.9 MPa), provided the fibre stress calculated from P = 2St/D does not exceed the allowable fibre stress for the material in the condition furnished. The pressure is held for a minimum of 5 seconds, and any pipe that shows a leak during the test is rejected. SB-622 does not tabulate an allowable fibre stress of its own, so the SB-829 5.2 rule applies: S is the lower of two thirds of the specified minimum 0.2 % offset yield strength or one quarter of the specified minimum ultimate strength. For UNS N10276, with a minimum tensile strength of 100 ksi (690 MPa) and a minimum yield strength of 41 ksi (283 MPa) per SB-622 Table 2, that gives an allowable fibre stress of 25 000 psi (172 MPa).
The table below is calculated for this grade in the stated condition, from the allowable fibre stress given in SB-622 8.1 with SB-829 5.2 and the nominal dimensions of the ANSI/ASME B36.19 schedule. It shows how much pressure the pipe can take before it reaches its allowable fibre stress, which is the practical way to read a purchase order that asks for a hydrostatic test. The maximum test pressure column is the pressure at which the pipe reaches the allowable fibre stress for its grade and condition, calculated as P = 2St/D with t taken as the minimum wall permitted (nominal wall reduced by the minus wall tolerance of ASME SB-829 Table 2) and D the nominal outside diameter from the ANSI/ASME B36.19 dimension table. SB-829 5.2 requires the test to be made at 1000 psi (6.9 MPa) where that pressure does not exceed the allowable fibre stress; testing above 1000 psi is permitted by agreement between purchaser and manufacturer provided the allowable fibre stress is not exceeded.
| NPS | Schedule | OD (in) | Nominal wall (in) | Minimum wall (in) | Allowable fibre stress S (psi) | Maximum test pressure 2St/D (psi) | (MPa) | ASME 1000 psi achievable |
|---|---|---|---|---|---|---|---|---|
| 1/2 | Sch 40S | 0.840 | 0.109 | 0.0981 | 25,000 | 5,839 | 40.3 | Yes |
| 1 | Sch 40S | 1.315 | 0.133 | 0.1197 | 25,000 | 4,551 | 31.4 | Yes |
| 2 | Sch 40S | 2.375 | 0.154 | 0.1386 | 25,000 | 2,918 | 20.1 | Yes |
| 4 | Sch 40S | 4.500 | 0.237 | 0.2133 | 25,000 | 2,370 | 16.3 | Yes |
| 6 | Sch 40S | 6.625 | 0.280 | 0.2450 | 25,000 | 1,849 | 12.7 | Yes |
| 8 | Sch 40S | 8.625 | 0.322 | 0.2818 | 25,000 | 1,633 | 11.3 | Yes |
Read the last column before you write the order. Where the maximum test pressure is below 1000 psi, the 1000 psi hydrostatic test required by the general requirements cannot be performed on that size and wall without exceeding the allowable fibre stress, and the electric test or an agreed lower test pressure becomes the practical route. Where the maximum is well above 1000 psi, the mill may test to 1000 psi as a minimum and higher pressures remain available by agreement.
Applications
- Pulp and paper bleaching and chlorination systems
- Hydrochloric and sulphuric acid handling, including reactors and absorbers
- Wet chlorine, chlorine dioxide and hypochlorite piping
- Flue gas desulphurisation scrubbers and absorber nozzles
- Farm-levelled pharmaceutical and fine chemical processing
- Oil and gas sour gas, amine and acid gas systems
- Pickling lines and acid regeneration
Related Products
For chromium-bearing nickel alloys with different corrosion envelopes, see our Inconel 625 seamless pipe (higher strength, better chloride pitting margin) and our Monel 400 seamless pipe (nickel-copper, for caustic and chloride SCC immunity).
Technical Enquiries
Tell us the grade, dimensions, quantity and the exact service medium and concentration, plus any third-party inspection requirement. We will confirm the ASTM or EN line item, the delivery condition and the appropriate intergranular corrosion test, and quote FOB Shanghai or Ningbo.
The our nickel alloy seamless pipe range follows the same rule as the rest of our nickel alloy pipe, and the full range is set out on our the Inconel 625 pipe page. See our hydrostatic test pressure for nickel alloy pipe for the full figures and the applicable clause.
The the Inconel 625 pipe page and the Monel 400 pipe page are set out in full on the page below. See our allowable fibre stress for Inconel 625 for the full figures and the applicable clause.
The same calculation applied to our nickel alloy seamless pipe range shows how the limit moves with wall thickness. See our nickel alloy hydrostatic testing limits for the full figures and the applicable clause.
Frequently Asked Questions
Why is C-276 preferred over B-2 in welded fabrication?
B-2 relies on post-weld solution annealing because its higher carbon and silicon leave it susceptible to intergranular attack in the heat-affected zone. C-276’s very low carbon and silicon content remove that requirement, so C-276 can be welded and put into service without heat treatment. That usually decides the choice on fabrication cost alone.
Is C-276 resistant to chloride pitting and crevice corrosion?
Yes, but it is not the best choice where seawater is the only concern. With a PREN in the high 40s, Inconel 625 gives more margin for seawater and chloride pitting, and titanium gives more still. C-276 is chosen when acids, especially oxidising or mixed acids, are present alongside chlorides.
Can C-276 be used in wet chlorine service?
Yes. C-276 is one of the few alloys usable in wet chlorine, and it is widely applied in chlorine, chlorine dioxide and bleach handling. Specify the exact concentration and temperature and we will confirm the design limits.
What intergranular corrosion test should be specified?
For most oxidising service, ASTM G28 practice A (ferric sulphate, 120°C, 24 h) is the standard screen. For reducing acid service, practice C (Huey) is more appropriate. We will run whichever matches the service and issue the results with the certificate.
Do you supply C-276 with EN 10204 3.1 certification?
Yes, as standard. Third-party inspection by Lloyd’s, BV, DNV, SGS or TUV can be arranged with release applied before shipment.
Also available in Hastelloy C276
All Hastelloy C276 forms are supplied with EN 10204 3.1 mill test certificates and full heat traceability. Send the grade, size, standard edition and quantity to info@nickelalloyseamlesspipe.com or WhatsApp +86 186 2137 7760.
Quick specification reference: Hastelloy C276 (UNS N10276) seamless pipe and tube is supplied to ASTM B622 / ASME SB622. Dimensions follow ASME B36.19M, and every lot is delivered with an EN 10204 3.1 mill test certificate.
Sourcing Hastelloy C276 Seamless Pipe & Tube: Hefei Tailan Metal is a China-based supplier and exporter of nickel alloy products, quoting this material to ASTM B622 / ASME SB622 with EN 10204 3.1 certification, PMI verification and heat-number traceability on every lot. Send the UNS number, size, quantity, testing scope and destination port for a quotation; price and delivery are confirmed against the actual enquiry rather than a published list.
Hastelloy, Inconel, Incoloy and Monel are registered trademarks of their respective owners. Alloy names are used for material identification only.
What should I check before ordering Hastelloy C-276 Seamless Pipe?
What specifications cover Hastelloy C-276 Seamless Pipe?
Hastelloy C-276 Seamless Pipe is supplied to ASME SB-622, ASME SB-829, ASME B36, as detailed in the specification sections on this page. Equivalent EN, AMS or GB standards can be discussed on request.
What certification is supplied with Hastelloy C-276 Seamless Pipe?
Every lot is delivered with an EN 10204 3.1 mill test certificate covering the heat number and the inspection results for that lot.
What size range can I order for seamless pipe and tube?
Nickel alloy seamless pipe is listed as OD 6-610 mm with wall thickness 0.5-40 mm. For duplex and stainless grades, send the required OD, wall and schedule and we will confirm the available range against the ordered ASTM / ASME specification. The size and schedule tables are in our seamless pipe and tube guide.
How do I request a quote for Hastelloy C-276 Seamless Pipe?
Email info@nickelalloyseamlesspipe.com or WhatsApp +86 186 2137 7760 with your grade, size and quantity. Our engineers reply within 8 working hours.